Fiberoptic Sensors for Non-Contact Displacement

 GENERAL SPECIFICATIONS - metric units

Standard D Models
Reflectance Dependent
image2.gif
The output voltage function for D model sensors includes a near side region where the voltage rises with increasing distance, an optical peak region, and a far side region where the voltage output decreases with increasing distance.  Operation in the near side region gives high sensitivity with limited operating range.  Operation in the far side region gives moderate sensitivity with greater operating range.
TIP   DETAILS
<
<
<
<
<
<
<
<
MODELS
>
>
>
>
>
FEATURES
UNITS
D6
D12
D20
D21
D47
D63
D64
D100
D125
D169
D170
D171
A
meters
0.91
0.91
0.91
0.91
0.91
0.91
0.91
 0.91 
 0.91
0.91
 0.91
0.91
A Dia.
mm
5.1
5.1
5.1
 5.1
5.1
5.1
5.1
5.1
 5.8
6.6
 6.6
6.6
B
mm
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
 12.7
15.2
 15.2
15.2
B Dia.
mm
6.35
6.35
6.35
6.35
4.6
6.35
6.35
6.35
 6.35
7.87
 7.87
7.87
C
mm
38.1
38.1
38.1
38.1
38.1
76.2
76.2
76.2
 76.2
76.2
 76.2
76.2
D
mm
0.81
0.81
0.81
0.81
1.6
3.18
3.18
3.18
 3.96
 4.76
 4.76
4.76
E
mm
0.16
0.51
0.51
.51
1.16
 1.59
1.59
2.54
 3.18
 4.29
 4.32
4.35
ß
degrees
30
30
66
30
30
66
30
30
30
30
25
25
        NOMINAL OUTPUT SPECIFICATIONS
UNITS
D6
D12
D20
D21
D47
D63
D64
D100
D125
D169
D170
D171
RANGE
mm
1
2
1.3
2
5
3
6
10
15.2
20
30
50
OPTICAL PEAK
mm
0.23
0.23
0.13
0.28
.28
0.15
0.3
0.43
0.48
0.56
1.0
9.6
 
NEAR
SIDE
D6
D12
D20
D21
D47
D63
D64
D100
D125
D169
D170
D171
Standoff
mm
0.05
0.08
0.03
0.08
.09
0.03
0.08
0.08
0.08
0.08
0.1
2.0
LinearRange ±1%
mm
0.04
0.05
0.02
0.03
0.02
0.02
0.04
0.04
0.05
0.06
0.06
1.9
Sensitivity
mv/micron
47
40
80
40
43
90
50
43
40
40
25
0.9
Resolution
DC - 100 Hz
nm
60
5
7
12
13
4
13
5
6
8
15
600
STD Resolution
DC-20 KHz
nm
330
50
25
50
40
8
50
32
20
38
40
900
Resolution D DC-200 KHz
micron
1.2
0.1
0.05
0.1
0.1
0.015
0.1
0.15
0.04
0.1
0.1
2.5
 
FAR
SIDE
D6
D12
D20
D21
D47
D63
D64
D100
D125
D169
D170
D171
Standoff
mm
0.43
0.53
0.3
0.7
1.75
0.66
1.1
2.0
2.1
2.5
4.8
15
Linear Range
±1%
mm
0.23
0.48
0.25
0.4
1.5
0.76
1.4
2.5
2.9
3.5
6.4
6.1
Sensitivity
mv/micron
5
3
8
3
1.4
2.8
1.6
0.8
0.6
0.5
0.3
0.3
Resolution
DC - 100 Hz
micron
0.1
0.04
0.06
0.15
0.1
0.12
0.5
0.75
0.25
0.43
1.2
1.7
Standard Resolution
DC - 20 KHz
micron
1.3
0.4
0.25
0.6
0.5
0.3
1.0
1.5
1.1
1.5
2.5
3
Resolution
DC-200 KHz
micron
4
1.2
.5
1.3
2
0.55
2.0
3.0
1.5
3.8
6.4
10
Range extends from 0 to the gap at which the far side output voltage is down to 10% of full scale.
Standoff equals the distance from the target to the center of the linear operating range.
Resolution (microns) = Sensor Noise(millivolts) / Sensitivity (micron/mv).
The standard sensor bandwidth is DC - 20KHz.
MINIMUM THREAD SIZES FOR SENSOR TIPS
MODEL
UNIFIED THREAD SIZES
METRIC THREAD SIZES
D6
6-32 UNC
M3 x 0.5
D20
6-32 UNC
M3 x 0.5
D21
6-32 UNC
M3 x 0.5
D47
8 - 32 UNC
M3 x 0.5
D63
8 - 32 UNC
M3 x 0.5
D64
8 - 32 UNC
M3 x 0.5
D100
10 - 32 UNC
M5 x 0.8
D125
1/4 - 28 UNF
M6 x 1
D169
5/16 - 24 UNF
M8 x 1.25
D170
5/16 - 24 UNF
M8 x 1.25
D171
5/16 - 24 UNF
M8 x 1.25