Sensors for Non-Contact Motion Control

 GENERAL SPECIFICATIONS - inch units

Standard D Models
Reflectance Dependent

The output voltage function for D model sensors includes a near side region where the voltage rises with increasing distance, an optical peak region, and a far side region where the voltage output decreases with increasing distance.  Operation in the near side region gives high sensitivity with limited operating range.  Operation in the far side region gives moderate sensitivity with greater operating range.
TIP   DETAILS
<
<
<
<
<
<
<
<
MODELS
>
>
>
>
>
FEATURES
UNITS
D6
D12
D20
D21
D47
D63
D64
D100
D125
D169
D170
D171
A
 feet
3
3
3
 3
3
3
 
 3
 3
 3
3
A Dia.
 inch
 0.2
 0.2
 0.2
 0.2
0.2
 0.2
 0.2
  0.2
 0.23
0.26
 0.26
0.26
B
 inch
 0.5
0.5
0.5
 0.5
0.5
 0.5
0.5
 0.5
 0.5
 0.6
 0.6
0.6
B Dia.
 inch
 0.25
0.25
0.25
 0.25
0.1875
 0.25
0.25
 0.25
 0.25
 0.31
 0.31
0.31
C
 inch
 1.5
 1.5
 1.5
 1.5
1.5
 3
 3
 3
 3
 3
 3
 3
D
 inch
 0.032
 0.032
 0.032
 0.032
0.065
.125
.125
.125
.156
.188
.188
.188

(F.O. Dia)
mils
6
20
20
20
0.047
 63
64
100
125
169
170
171
ß
degrees
30
30
66
30
30
66
30
30
30
30
25
25
        NOMINAL OUTPUT SPECIFICATIONS
UNITS
D6
D12
D20
D21
D47
D63
D64
D100
D125
D169
D170
D171
RANGE
mils
40
80
50
80
200
120
240
400
600
750
1200
2000
OPTICAL PEAK
mils
9
9
5
11
12
6
12
17
19
22
39
380
 
NEAR
SIDE
D6
D12
D20
D21
D47
D63
D64
D100
D125
D169
D170
D171
Standoff
mils
3
3
1.2
3.2
3.2
1.2
2.4
2.5
3
3.3
4
80
Linear Range, ±1%
mils
1
1.9
0.75
1.9
0.8
0.75
1.5
1.5
2
2.3
2.5
75
Sensitivity
mv/microinch
1.2
1.0
2.0
1.0
1.1
2.2
1.3
1.1
1.0
1.0
0.6
0.02
Resolution
DC - 100 Hz
microinch
2
0.2
0.25
0.5
0.5
0.14
0.5
0.2
0.25
0.3
0.6
25
STD Resolution
DC - 20 KHz
microinch
17
2
1
10
2.0
0.3
2.0
1.25
0.75
0.75
1.2
35
Resolution

DC-200 KHz

microinch
35
4
2
20
4.0
0.6
4
6
1
2
2.5
100
 
FAR
SIDE
D6
D12
D20
D21
D47
D63
D64
D100
D125
D169
D170
D171
Standoff
mils
17
21
12
28
70
26
45
80
85
100
190
600
Linear Range, ±1%
mils
9
19
10
16
60
30
52
100
115
140
250
240
Sensitivity
mv/mil
200
120
210
80
1.4
70
40
21
16
13
8
7
Resolution
DC - 100 Hz
microinch
5
1.5
2.5
6
4
5
20
30
10
17
50
65
STANDARD Resolution
DC - 20 KHz
microinch
50
16
10
25
20
11
40
60
45
60
100
110
Resolution
DC - 200 KHz
microinch
150
50
20
50
80
22
80
120
60
150
250
400
Range extends from 0  to the gap at which the far side output voltage is down to 10% of full scale.
Standoff equals the distance from the target to the center of the linear operating range.
Resolution (microinches) = Sensor Noise(millivolts) / Sensitivity (mv/microinch).
The standard sensor bandwidth is DC - 20KHz.
Conversions: 1 mil = 0.001"    1 microinch = 0.000001"
MINIMUM THREAD SIZES FOR SENSOR TIPS
MODEL
UNIFIED THREAD SIZES
METRIC THREAD SIZES
D6
6-32 UNC
M3 x 0.5
D20
6-32 UNC
M3 x 0.5
D21
6-32 UNC
M3 x 0.5
D47
8 - 32 UNC
M3 x 0.5
D63
8 - 32 UNC
M3 x 0.5
D64
8 - 32 UNC
M3 x 0.5
D100
10 - 32 UNC
M5 x 0.8
D125
1/4 - 28 UNF
M6 x 1
D169
5/16 - 24 UNF
M8 x 1.25
D170
5/16 - 24 UNF
M8 x 1.25
D171
5/16 - 24 UNF
M8 x 1.25