Sensors for Non-Contact Distance

OPTIONS FOR SENSORS

You can link to descriptive details on many of these options by clicking on the option letter in the table below. These links are in the Adobe pdf format.
You will need to obtain Adobe Acrobat Reader to view these details!

The standard PHILTEC sensor package provides a stainless steel sensor tip, a 3 foot long fiberoptic cable sheathed with PVC over steel monocoil, and DC-20 KHz bandwidth amplifier or DMS signal processing unit as one integral unit with the fiberoptic cable potted into the electronic enclosure.  Many options are available whereby the sensor tip, fiberoptic cable and/or the sensor electronics can be customized.  Several options can be combined into one unit and specified using the following format:  Model D100-BC1LT for analog units or Model DMS-RC100-BC1LT for digital units.

Important Note: It should be realized that certain combinations of options are not achievable for all models.  For example, it is not reasonable to expect to achieve high frequency response when combining replaceable tips with long fiberoptic cables and dark targets.  Please consult with the factory when there are questions regarding such issues.
 
OPTION CODE
FOR
DMS
FEATURE
A N Temperature Stabilized Amplifier
B
Y
Replaceable Tip Configuration - In-Line Connector
B1
Y
Replaceable Tip Configuration - Sensor Bulkhead Connector
Bv1
Y
Single Channel Vacuum Passthru Connection for 10 E-7 Torr (not available for D6, D12 or RC12)
Bv2
Y
Single Channel Ultra-High Vacuum Configuration for all D models 
(not available for D6 or D12).
Bv3
Y
Single Channel Ultra-High Vacuum Configuration for all RC models
(not available for RC12).
Bvf
Y
High Vacuum Fiberoptic Passthru, Single or Multichannel
(not available for D6, D12, RC12).
Y
Weldable Single Port Vacuum Passthru. D Models Require 2; RC Models Require 3
C1
Y
Cable Sheathing: Stainless Steel Interlok Hose for Maximum Strength & 425°C
C2
Y
Cable Sheathing: Silicone Rubber for max. flexibility, no crush resistance, 232°C
C3
Y
Cable Sheathing: Silicone over Plastic Spiral Wrap, non-metallic light crush resistance, short lengths only, 2 meters maximum.
C4
Y
Cable Sheathing: Silicone Over Steel Monocoil, 232°C with light crush resistance
C5
Y
Cable Sheathing: Teflon Over Stainless Steel Interlok for Vapor Barrier
C6
Y
Cable Sheathing: PVC Low Temperature Shrinkwrap over Nylon Spiral Wrap, non-metallic with light crush resistance, good for  long lengths
C7
Y
Cable Sheathing: Translucent Teflon. For high vacuum applications. Does not outgas. Wide temperature range, poor flexibility, susceptible to light interference.
Y
Cable Sheathing: PVC Low Temperature Shrinkwrap only, non-metallic with no crush resistance, good for long lengths
C9
Y
Annealed (semi-rigid) Stainless Steel Tubing
C10
Y
Silicone Over SS Interlok Sheathing
D
Y
Reflectance Dependent Output
E
Y
Standard Cable Lengths are 3 feet. For lengths exceeding 3 ft., specify Option E and give total Cable Length, 49 Feet Maximum (15 m).
Fv1 & Fv2
Y
Solid Section On Fiberoptic Cable For Low Vacuum Passthru, 10 E-4 Torr Max.
G1
N
Equips Sensor With An Additional Output, DC Coupled with 10x Gain and Adjustable DC Offset
G2
N
Equips Sensor With An Additional Output, AC Coupled with 10x Gain
H1
N
Provides D models with a high bandwidth amplifier, DC - 200 KHz
H2
N
Provides D models with a high bandwidth amplifier above 200 KHz. 
Bandwidths up to 1.5 MHz (some models) can be specified.
H3
N
Provides RC models with a high bandwidth amplifier, DC - 200 KHz.
Bandwidths up to 350 KHz can be specified.
+Hn
N
Designating +H1 or +H2 or +H3 provides a sensor amplifier with two outputs: standard DC-20 KHz and a wideband output.
L
N
Equips sensors with a low bandwidth amplifier, DC-100Hz. 
Bandwidths as low as 10 Hz can be specified. 
+L
N
Equips a sensor amplifier with two outputs: 
standard DC-20 KHz and a low frequency output, DC - 100 Hz 
M
N
Digital Display - DC Volts
N
N
Low Noise Amplifier - The amplifier is optimized to operate with highly reflective targets only. This cuts noise floor in half, thereby doubling resolution (For RC sensors only)
O
N
Provides an adjustable 0 to -4 VDC offset control.  This feature is used to eliminate the DC offset from the sensor output, thereby increasing readout resolution.
P
N
Polynomial Curve Fit For Operation In Non-Linear Ranges
Q
N
Quick Disconnect AC Power Adaptor and BNC Output Connector
R
Y
Ambient Light Rejection - These devices operate with continuous light emission.  Standard units are subject to ambient light pickup.  In environments where background light is a problem, Ambient Light Rejection can be included by specifying Option R.  Ambient light pickup can be 50 to 100 times smaller when Option R is used. 
(Not available for models D6, D12).
S
Y
Side-Viewing Sensor Tip
T1 - T9
Y
Custom Sensor Tips
V
N
Provides Sensor Amplifiers with 0 - 10 Volt Analog Output
W
Y
Window Probe For High Pressure or Vacuum
Z
N
Additional Output with Linear Range Spanning 0 - 5 volts