Non-Contact Displacement Sensors

  SUMMARY OF MODELS

 D Models 
 Reflectance Dependent 
RC Models
Reflectance Compensated 
D Models include near side, peak, and far side regions and require calibration to target surfaces.
RC Models have a single-valued output and do not require calibration to target surfaces.

D MODELS
Operating Range
mm
Resolution DC- 20KHz
Far Side Microns
D6
1
1.3
D20
1.3
0.4
D21
2
1.1
D47
5
0.5
D63
3
0.6
D64
6
1.1
D100
10
1.1
D125
15
1.1
D169
20 
1.3
D170
30 
1.6
D171
50
9
RC MODELS
Operating Range
mm
Resolution DC- 20 KHz
 Microns
RC12
0.5
0.2
RC25
0.8
0.33
RC20
1.3
0.8
RC62
2.0
0.9
RC60
3.2
1.5
RC63
4.0
1.8
RC100
5.0
2.8
RC140
10
2
RC90
8.9
3.4
RC171
12.7
7
RC190
14
6